Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Well-run equipment, professional sales team, and better after-sales services; We are also a unified big family, everyone stick to the company value "unification, dedication, tolerance" for Room Ventilator Heat Recovery, Air Conditioner Heat Recovery Unit, Air To Air Heat Recovery Ventilator, We give priority to quality and customer satisfaction and for this we follow stringent quality control measures. We have in-house testing facilities where our products are tested on every aspect at different processing stages. Owning to latest technologies, we facilitate our customers with customized production facility.
Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV Detail:

ERD Cross&Counter Flow Heat exchanger Core
Cross & counter flow heat exchanger core is made of antiseptic hydrophilic/aluminum foil and galvanized sheet cover.A part of air is cross flow, and the other is counter flow, combined the working methods both cross flow and counter flow heat exchanger core, achieve more higher heat efficiency.
It is usually being used for recovering energy at residential household, commercial and industrial ventilation systems.

1 2

Feature:
1.Adopt antiseptic hydrophilic aluminium, resistant to corrosion, with long service life.
2.Module and compact structure, no use of rivets or screws.
3.No running components, low maintenance cost.
4.Suitable for washing with water or neutral detergent.
5. Extremely high strength and pressure related stability.

Production Technology:
1.The surface of heat exchanger core was processed with heat transfer enhancement techniques, increased the 10% heat transfer area.
2.Convex and concave air channel, ensure the strength and tightness of heat exchanger core, could bear high pressure.
3.Counter air channel, double folding process of the face side edges, which is equal to 5 times material thickness, ensure the high intensity and tightness.
4. All joints are airproofed by airproof glue, ensured that the heat exchanger core has excellent air tightness.

3

Model Range:

126

Application:
The cross flow and counter flow heat exchanger core is the major part of heat recovery ventilator(HRV).The heat exchanger core work for ventilation, recover the heat energy in winter and cold energy in summer, not only save the energy but also give room for fresh air.

Combination:

212121

Package and Delivery:
Packaging Details: carton or plywood case.
Port: Xiamen port, or as requirement.
Transport Way: by sea, air, train, truck, express etc.
Delivery Time: as below.

  Samples Mass production
Products Ready: 7-15 days To be negotiated

0180128


Product detail pictures:

Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV detail pictures

Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV detail pictures

Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV detail pictures

Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV detail pictures

Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV detail pictures

Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV detail pictures

Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV detail pictures

Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV detail pictures

Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV detail pictures

Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV detail pictures


Related Product Guide:

We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of Manufactur standard Telecom Building Air Exchanger - ERD Cross&Counter Flow Heat Exchanger – AIR-ERV , The product will supply to all over the world, such as: Haiti, Mauritius, Colombia, We honor ourselves as a company that comprises of a strong team of professionals who are innovative and well experienced in the international trading, business development and product advancement. Moreover, the company stays unique among its competitors due to its superior standard of quality in production, and its efficiency and flexibility in business support.
  • The enterprise has a strong capital and competitive power, product is sufficient, reliable, so we have no worries on cooperating with them.
    5 Stars By Florence from Brazil - 2017.08.18 18:38
    This is a honest and trustworthy company, technology and equipment are very advanced and the prodduct is very adequate, there is no worry in the suppliment.
    5 Stars By Ida from Uzbekistan - 2018.10.31 10:02
    Write your message here and send it to us